to main content Temperature and Humidity Requirements – Guidance for Storage of Sterile Supplies | Critical Access Hospital | Infection Prevention and Control IC | The Joint Commission
Coronavirus Resources
  • Careers
  • E-Alerts
  • Contact Us
Main Menu
The Joint Commission
Visit Joint Commission ResourcesVisit Joint Commission InternationalQuality Check
Login
  • Who We Are
    Through leading practices, unmatched knowledge and expertise, we help organizations across the continuum of care lead the way to zero harm.
    • Who We Work With
      • Our Partnerships
      • Payor Relations
      • State Recognition
    • Why Work With Us
    • Facts About The Joint Commission
      • History of The Joint Commission
      • Joint Commission FAQs
      • Board of Commissioners
      • Joint Commission Advisory Groups
      • Quality Check and Quality Reports
    • Policies and Financials
      • Code of Conduct
      • Conflict of Interest Policy
      • Designated Copyright Agent Policy
      • Financial Statements
      • Firewall Policy Summary
      • Linking to The Joint Commission Website
      • Public Information Policy
      • Reprint Permission Policy
    • Federal Relations and Public Policy
    • Joint Commission Officers
      • Jonathan B. Perlin
      • David Baker
      • Brian Enochs
      • Michael Kaba
      • Kin Lee
      • Ana Pujols McKee
      • Paige Rodgers
      • Deborah A. Ryan
      • Margaret VanAmringe
      • Lisa Vandecaveye
    • Joint Commission Resources
    • Joint Commission International
    A doctor reviews information on a tablet with a nurse

    Who We Work With

    Learn more about the communities and organizations we serve.

    A group of business professionals collaborate on a project in a conference room

    Why Work With Us

    See how our expertise and rigorous standards can help organizations like yours.

  • What We Offer
    In addition to accreditation, certification, and verification, we provide tools and resources for health care professionals that can help make a difference in the delivery of care.
    • How We Can Help
    • Accreditation
      • Health Care Settings
      • Become Accredited
      • Accreditation Guide
      • Accredited
    • Certification
      • What is Certification
      • Certifications by Setting
      • Explore Eligibility
      • Learn the Process
      • After your Review
      • Certifications without Accreditation
    • Verification
      • Improve Maternal Outcomes at Your Health Care Facility
      • Maternal Levels of Care Verification
      • Publicity Kit
    • Complimentary Resources
      • Webinars
      • Newsletters
      • R3 Reports
      • Sentinel Event Alerts
      • Patient Safety Topics
      • DASH
    Female nurse holding senior woman's hand.

    How We Can Help

    Learn how working with the Joint Commission benefits your organization and community.

    Shot of a group of medical practitioners having a discussion in a hospital.

    Accreditation Guide

    Find the exact resources you need to succeed in your accreditation journey.

  • Our Priorities
    Learn about the priorities that drive us and how we are helping propel health care forward.
    • Health Care Equity
      • Accreditation Standards & Resource Center
    • Emergency Management
    • Infection Prevention and Control
    • Suicide Prevention
    • Workplace Violence Prevention
    An elderly woman in a wheelchair is helped by a friendly nurse

    Health Care Equity

    Drive performance improvement using our new business intelligence tools.

    Veterinarian washing hands with soap at sink

    Infection Prevention & Control

    Find evidence-based sources on preventing infections in clinical settings.

  • Standards
    Set expectations for your organization's performance that are reasonable, achievable and survey-able.
    • About Our Standards
    • Standards Field Reviews
      • Proposed Requirements Related to Environmental Sustainability Field Review
    • National Patient Safety Goals
      • Ambulatory Health Care: 2023 National Patient Safety Goals
      • Assisted Living Community: 2023 National Patient Safety Goals
      • Behavioral Health Care and Human Services: 2023 National Patient Safety Goals
      • Critical Access Hospital: 2023 National Patient Safety Goals
      • Home Care: 2023 National Patient Safety Goals
      • Hospital: 2023 National Patient Safety Goals
      • Laboratory Services: 2023 National Patient Safety Goals
      • Nursing Care Center: 2023 National Patient Safety Goals
      • Office-Based Surgery: 2023 National Patient Safety Goals
    • Prepublication Standards
      • New Requirements for Certified Community Behavioral Health Clinics
      • Revision to MS.06.01.05, EP 7
      • The Term Licensed Independent Practitioner Eliminated
      • Updates to the Patient Blood Management Certification Program Requirements
      • New Assisted Living Community Accreditation Memory Care Certification Option
      • Revisions to PI.01.01.01, EP 4
      • Health Care Equity Standard Elevated to National Patient Safety Goal
      • New and Revised Emergency Management Standards
      • New Health Care Equity Certification Program
      • Updates to the Advanced Disease-Specific Care Certification for Inpatient Diabetes Care
      • Updates to the Assisted Living Community Accreditation Requirements
      • Updates to the Comprehensive Cardiac Center Certification Program
    • R3 Report
    • Standards FAQs
    • Universal Protocol
    • Patient Safety Systems PS Chapter
    Nurse and doctor talking to happy hospital patient after surgery

    National Patient Safety Goals

    Find out about the current National Patient Safety Goals (NPSGs) for specific programs.

    doctor chatting to sales rep in hospital corridor

    FAQs about the Standards

    We help you measure, assess and improve your performance.

  • Measurement
    Learn about the "gold standard" in quality. We develop and implement measures for accountability and quality improvement.
    • Measures
      • Assisted Living Community Measures
      • Cardiac Care
      • Emergency Department
      • Health Care Staffing Services
      • Hospital Outpatient Department
      • Hospital-Based Inpatient Psychiatric
      • Immunization
      • Palliative Care
      • Perinatal Care
      • Spine Surgery
      • Stroke
      • Substance Use
      • Tobacco Treatment
      • Total Hip and Knee Replacement
      • Venous Thromboembolism
    • Specifications Manuals
      • Electronic Clinical Quality Measures
      • Chart Abstracted Measures
    • Reporting
      • Accreditation - Hospital
      • Certification
    • Pioneers in Quality
      • Facts
      • Proven Practices
      • Expert to Expert Series
      • Recognition
    • Resources
    • ORYX FAQs
    • Quality Measurement Webinars & Videos
      • Video Shorts
    • Assisted Living Community (ALC)
    Business information and info-graphics concept.

    Measures

    Learn about the development and implementation of standardized performance measures. View them by specific areas by clicking here.

    Happy Medical Team Looking at Laptop in Doctor's Office.

    Pioneers in Quality

    Gain an understanding of the development of electronic clinical quality measures to improve quality of care.

  • Resources
    Obtain useful information in regards to patient safety, suicide prevention, infection control and many more.
    • Health Care Equity
    • Publicity Kits
    • Patient Safety Topics
      • Zero Harm
      • Emergency Management
      • Health Care Workforce Safety and Well-Being
      • Infection Prevention and Control
      • Report a Patient Safety Concern or Complaint
      • Suicide Prevention
      • Workplace Violence Prevention
    • News & Multimedia
      • The Joint Commission Stands for Racial Justice and Equity
      • Blogs
      • Joint Commission Saves Lives
      • Events
      • Fact Sheets
      • Newsletters
      • News Releases
      • Podcasts
      • Speakers Bureau
      • Video Resources
      • Webinars
      • The Joint Commission and Social Media
    • Patient Safety
      • 2022 Patient Safety Awareness Week
    • Sentinel Event
    • The Physical Environment
      • Utility Systems - EC.02.05.01
      • Means of Egress - LS.02.01.20
      • Built Environment - EC.02.06.01
      • Fire Protection - EC.02.03.05
      • General Requirements - LS.02.01.10
      • Protection - LS.02.01.30
      • Automated Suppression - LS.02.01.35
      • Life Safety Code
    • For Nurses
    • For Physicians
      • Physician Leader Monthly March 2023
      • Physician Leader Monthly February 2023
      • Physician Leader Monthly January 2023
      • Physician Leader Monthly December 2022
      • Physician Leader Monthly November 2022
      • Physician Leader Monthly October 2022
      • Physician Leader Monthly September 2022
      • Physician Leader Monthly August 2022
      • Physician Leader Monthly July 2022
      • Physician Leader Monthly June 2022
      • Physician Leader Monthly May 2022
      • Physician Leader Monthly April 2022
    • For Consumers
      • Speak Up Campaigns
      • COVID-19 Vaccines
      • TakeCHARGE
      • The Joint Commission Journal on Quality and Patient Safety
      • The Smart Parents Guide
      • You The Smart Patient
    • Research
      • Operations Support Research
      • Evaluation Research
      • Health Services Research
      • DataMart
    • Awards
      • Ernest Amory Codman Award
      • John M. Eisenberg Patient Safety and Quality Award
      • Bernard J. Tyson National Award for Excellence in Pursuit of Healthcare Equity
    • Continuing Education Credit Information
      • Continuing Education Credit Information FAQs
    Talking to audience.  One member of the board speaking in microphone among other participants of meeting.

    News & Multimedia

    Stay up to date with all the latest Joint Commission news, blog posts, webinars, and communications.

    Group of young creative people collaborating in modern office.

    Patient Safety Topics

    We can make a difference on your journey to provide consistently excellent care for each and every patient.

  1. Home >
  2. Standards >
  3. Standards FAQs >
Temperature and Humidity Requirements – Guidance for Storage of Sterile Supplies
Print

Do we need to monitor the temperature and humidity of the rooms where sterile supplies are stored?

Back to FAQs
Any examples are for illustrative purposes only.

When developing Infection Prevention related policies and practices, it's important that you refer to the Infection Prevention Hierarchy, published in the April 2019 Perspectives.

The first level of the hierarchy is that you ensure your organization is compliant with all building code requirements.  Deemed organizations must fulfill, Centers for Medicare and Medicaid (CMS) ventilation requirements which outline criteria for new or renovated existing facilities (constructed or plans approved on or after July 5, 2016). These are provided in the 2012 edition of NFPA 99 which references the 2008 edition of ASHRAE 170 table 7.1.  If your local authority has published building codes, then your organization must meet the most restrictive requirement.

ASHRAE Standard 170- 2008 Table 7.1 ventilation requirements for sterile storage in CENTRAL MEDICAL AND SURGICAL SUPPLY areas includes the following:
  • Positive air pressure relationship to adjacent areas
  • Minimum outdoor air exchange 2 per hour
  • Minimum total air exchange 4 per hour
  • Maximum relative humidity 60%
  • Temperature range 72 to 78 F or 22 to 26 C

Organizations with existing facilities, constructed or plans approved prior to July 5, 2016, may comply with the 2012 ventilation requirements in NFPA 99 or the version of NFPA 99 in effect at the time of the ventilation system installation. 

The next level of the hierarchy is the CMS Infection Control Worksheet for the Hospital (HAP) and Ambulatory Surgical Center (ASC).  Depending on the type of facility surveyed, these organizations must meet Conditions of Participation (CoP) or Conditions for Coverage (CfC). The worksheet provides the following guidance for surveyors for reusable items sterilized on site:

  • (HAP) After sterilization, medical devices and instruments are stored so that sterility is not compromised.
  • (ASC) After sterilization, medical devices and instruments are stored in a designated clean area so that sterility is not compromised
  • (ASC and HAP) Sterile packages are inspected for integrity and compromised packages are repackaged and reprocessed prior to use.

Next, organizations must be compliant the manufacturer's instructions for storage.  If, for example, the manufacturer of the sterile supply requires a specific temperature and humidity requirement for storage, your organization would need to demonstrate at the time of survey that these requirements are being met.  The Joint Commission does not specifically require that these parameters be documented, however your staff should be able to identify if any sterilized supply, whether single use or reprocessed, has been potentially compromised (as may occur if the integrity of the package is in question or has evidence of damage from humidity) and can speak to whether that item would be appropriate for use.

Finally, your organization may refer to evidence-based guidelines and national standards (EBGs) for guidance as to how sterile supplies should be stored.  Most EBGs agree that sterile supply areas must be clean, well ventilated and protect supplies from contamination, moisture, dust, temperature extremes, and humidity extremes. Your organization must show evidence that, whether in a designated Central Surgical Supply area or in a storage room with mixed clean and sterile supplies, you are storing those supplies in a manner to protect from contamination and maintain the integrity of the packaging from damage.  Failure to store medical and sterile supplies in a manner to protect from contamination will be scored at IC.02.02.01 EP 4.

References and applicable standards:
IC.02.02.01
EC.02.05.01
NFPA 99-2012: 9.3.1
ASHRAE 170-2008
2018 FGI Guidelines

Additional Resources:
A read only copy of the ASHRAE standard can be accessed from this hyperlink: ASHRAE then scroll down the list to Standard 170-2008 Ventilation of Health Care Facilities.
CMS Hospital Infection Control Worksheets
CMS - Ambulatory Surgical Center (ASC) Infection Control Worksheet
Guideline for Disinfection and Sterilization in Healthcare Facilities (2008)
Guidelines for Design and Construction of Health Care Facilities 2018 edition

Manual: Critical Access Hospital
Chapter: Infection Prevention and Control IC
Last reviewed by Standards Interpretation: October 19, 2021 Represents the most recent date that the FAQ was reviewed (e.g. annual review).
First published date: April 11, 2016 This Standards FAQ was first published on this date.
This page was last updated on May 20, 2022 with update notes of: Review only, FAQ is current Types of changes and an explanation of change type: Editorial changes only: Format changes only. No changes to content. | Review only, FAQ is current: Periodic review completed, no changes to content. | Reflects new or updated requirements: Changes represent new or revised requirements.
Back to FAQs

If no, please comment on how we could improve this response.

If you have additional standards-related questions regarding this topic, please use the Standards Online Submission Form
A group of nurses in a hospital hallway

Go Above and Beyond with Certification

Certifications from The Joint Commission represent the most stringent, comprehensive and evidence-based proof of the success of your program available.
Certification
A team of surgeons in the operating room

Additional Resources

Train your staff with a tool to quickly and efficiently assess standards compliance with our Hospital Compliance Assessment Workbook.

Additional hospital resources
A group of professionals sitting together in a meeting

Hospital Webinars

Keep learning with our Hospital Breakfast Briefings Webinar Series. Get a deep dive into our standards, chapter-by-chapter, individually or as a team.

Hospital Breakfast Briefings
Chat Bot Icon
Joint Commission Virtual Assistant
This site uses cookies and other tracking technologies to assist with navigation, providing feedback, analyzing your use of our products and services, assisting with our promotional and marketing efforts, and provide content from third parties. Get more information about cookies and how you can refuse them by clicking on the learn more button below. By not making a selection you will be agreeing to the use of our cookies.
  • Joint Commission International
  • Joint Commission Resources
  • Visit us on Facebook facebook
  • Visit us on Twitter twitter
  • Visit us on LinkedIn linkedin
  • News Room
  • Careers
  • E-Alerts
  • Contact Us
  • Accessibility
  • Terms of Use
  • Privacy & Cookies Statement
©2023 The Joint Commission, All Rights Reserved

The Joint Commission is a registered trademark of the Joint Commission enterprise.